Dew Point Calculator: Humidity, Condensation and Mold Risk
How the dew point calculator works: at 68 °F (20 °C) and 50 % relative humidity the dew point is 48.7 °F (9.3 °C). Any surface colder than that gets wet with condensation. Mold can start earlier – from about 80 % humidity at the surface, here below 54.7 °F (12.6 °C).
Example: Temperature unit: °F (Fahrenheit) · What do you know: Temperature + relative humidity → dew point · Air temperature 68 · Relative humidity 50 % · Surface temperature (wall, window) 57 → Result: Dew point 48.7 °F (at 68 °F and 50 %). Source: WMO-No. 8, WMO-No. 8, Guide to Instruments and Methods of Observation, Vol. I, Ch. 4, Annex 4.B – Magnus formula e_w = 6.112 exp(17.62 t/(243.12 + t)). Updated: .
How it is calculated
What is the dew point?
The dew point is the temperature to which air must cool for its water vapor to start condensing – relative humidity then reaches 100 %. When indoor air cools below its dew point at a cold wall, window or pipe, water condenses there. Outdoors, the US National Weather Service calls dew points of 65 °F and more oppressive.
Dew point formula (Magnus)
The saturation vapor pressure over water follows the Magnus formula with the coefficients published by the World Meteorological Organization (WMO-No. 8):
e_s(t) = 6.112 hPa · exp(17.62 · t / (243.12 + t)), t in °C
- Vapor pressure of the air: e = relative humidity × e_s(t)
- γ = ln(e / 6.112)
- Dew point: τ = 243.12 · γ / (17.62 − γ)
Example 68 °F (20 °C), 50 %: e_s = 23.33 hPa, e = 11.66 hPa, γ = 0.646, τ = 9.3 °C = 48.7 °F.
Dew point chart (°F)
| Air | 40 % | 50 % | 60 % | 70 % |
|---|---|---|---|---|
| 65 °F | 40 °F | 46 °F | 51 °F | 55 °F |
| 68 °F | 43 °F | 49 °F | 54 °F | 58 °F |
| 72 °F | 46 °F | 52 °F | 57 °F | 62 °F |
| 75 °F | 49 °F | 55 °F | 60 °F | 65 °F |
| 80 °F | 54 °F | 60 °F | 65 °F | 69 °F |
Mold on walls: the 80 % rule
Mold doesn’t need liquid water. According to the German Environment Agency’s mold guideline, a surface relative humidity of about 70–80 % over longer periods is enough, while below 70 % mold hardly grows. Because air cools at a cold wall, its relative humidity rises there. The calculator therefore shows the surface temperature at which 80 % is reached – 54.7 °F (12.6 °C) for room air at 68 °F and 50 %.
Limitations
The Magnus formula is an approximation (under 0.5 % deviation from exact tables in the usual range) and applies from about −45 °C to 60 °C. Consumer hygrometers are often only accurate to ±3–5 %. Moisture analysis of whole wall assemblies (vapor retarders, insulation layers) needs the layer build-up and heat flow – that calls for a professional assessment.
Frequently asked questions
How do you calculate the dew point?
With the Magnus formula: get the vapor pressure from temperature and relative humidity, then γ = ln(e/6.112) and τ = 243.12 · γ / (17.62 − γ) in °C. At 68 °F and 60 % the dew point is 53.6 °F (12.0 °C).
What is a comfortable dew point?
The US National Weather Service rates summer dew points up to 55 °F as dry and comfortable, 55–65 °F as sticky with muggy evenings and 65 °F or more as oppressive.
How do I know if my wall will get mold?
Measure the coldest spot (room corner, window reveal) with an infrared thermometer and enter it as surface temperature. If humidity at the surface stays above 80 % for long periods, mold is likely.
What is the difference between relative and absolute humidity?
Absolute humidity is the mass of water per cubic metre of air. Relative humidity is the percentage of the maximum possible at that temperature – so it rises when the same air cools.
Why do windows fog up in winter?
The glass is colder than the dew point of the room air. At 68 °F and 50 %, glass below 48.7 °F fogs up. Ventilating lowers the moisture content and with it the dew point.
Sources and legal basis
- WMO-No. 8: WMO-No. 8, Guide to Instruments and Methods of Observation, Vol. I, Ch. 4, Annex 4.B – Magnus formula e_w = 6.112 exp(17.62 t/(243.12 + t))
- UBA Schimmelleitfaden: Umweltbundesamt – Leitfaden zur Vorbeugung, Erfassung und Sanierung von Schimmelbefall in Gebäuden (surface humidity 70–80%)
- NWS: US National Weather Service – dew point comfort levels
As of: · Editorial policy
Related tools
- Wet Bulb CalculatorWet bulb calculator: wet-bulb temperature from air temperature, relative humidity and pressure, using the National Weather Service formula. In °F or °C.
- Sea level pressure calculatorSea level pressure calculator: convert your barometer’s station pressure and elevation to sea level pressure (altimeter setting) and back, in inHg, hPa or mmHg.
- Cloud Base CalculatorCloud base calculator: estimate the cloud base height above ground from temperature and dew point with the FAA rule (spread ÷ 4.4 °F × 1,000 ft).
- Air purifier size calculatorAir purifier size calculator: the minimum CADR for your room area and ceiling height from the EPA sizing chart – or the largest room a given CADR can serve.
- Dehumidifier size calculatorDehumidifier size calculator: the minimum capacity in pints (and liters) per day for your room size and dampness, from the ENERGY STAR capacity chart.
- VPD calculator (vapor pressure deficit)VPD calculator: vapor pressure deficit in kPa from air temperature and relative humidity, optional leaf VPD, plus the humidity deficit in g/m³ – °F or °C.
- kg to lbs converterConvert kg to lbs and back: 1 kg = 2.2046 lb. Shows pounds and ounces, stone and pounds, grams, tons and a kg to lbs chart – exact to the legal definition.
- Epoxy resin calculatorEpoxy resin calculator: how much resin a tabletop, river table, round tray or mold needs – volume, weight and the split into resin and hardener.
- Heating Oil Usage CalculatorHeating oil usage calculator: how long will 100 gallons last? Work out gallons per day from your burner’s gph or Btu input and the days your tank will last.